Exterior
Slate/tile roof covering
Battens
Counter-battens
Ampatop Aero breathable membrane, taped with Ampacoll Flexx airtightness tape
200mm rafters, fully filled with SteicoFlex flexible wood fibre insulation
Ampatex Sinco vapour control membrane, taped with Ampacoll INT airtightness tape
25mm counter-batten
12mm plasterboard
Interior
(Use the shift button and scroll wheel to manipulate models)
U-Value
0.201W/m2K at 600mm rafter centres, 0.216 W/m2K at 400mm rafter centres