Can You Mix External and Internal Wall Insulation? – Can I Just Ask? | Ep.22

Mixed insulation strategies are sometimes unavoidable on retrofit projects, especially where architectural features or planning constraints limit the use of external wall insulation (EWI). Combining EWI and internal wall insulation (IWI) can work extremely well – provided the junctions are carefully detailed to avoid thermal bridging and moisture risks. Here’s how to approach it.

Prefer to watch Chris and Andy from our technical team go through this question. Check out the latest episode of Can I Just Ask? Watch Now!👇

Retrofitting older buildings often means working with a patchwork of facades: an ornate front elevation that must remain untouched, a pair of gable walls that no one has sentimental attachment to, and a rear elevation that’s ripe for improvement. It’s a familiar scenario in which project teams ask whether they can use external insulation on some elevations and internal insulation on others.

The short answer is yes – mixing EWI and IWI is entirely feasible – but doing it well relies on thoughtful junction design and a sensible strategy for transitioning between the two systems.


Minimising and Managing Transitions

Every change from internal to external insulation creates a junction, and every junction is a potential weak point. The priority should be to minimise the number of transitions across the building envelope. Fewer junctions mean fewer opportunities for thermal shortcuts and fewer areas where moisture behaviour becomes difficult to predict.

Where transitions are unavoidable, the junction needs to be designed to keep the thermal envelope continuous. This is typically achieved by overlapping the insulation layers so they effectively interlock, ensuring heat cannot easily bypass the insulated zone.


Achieving Continuity Without Excess Thickness

A common concern is whether the full thickness of insulation used on the main elevation must be ‘returned’ down the adjoining wall. Fortunately, the answer is usually no.

For example, imagine a project using 100 mm IWI on the front elevation and 100 mm EWI on the side and rear. Rather than returning a full 100 mm of internal insulation along the side wall, you can often use a much thinner internal board – around 20 mm – to create the necessary overlap. In practice, the external insulation might extend 500 mm or so past the corner, with the thin internal board meeting it from the inside.

This arrangement preserves continuity without creating bulky build-ups or awkward internal detailing. It’s a simple manoeuvre, but one that avoids many headaches later.


Choosing Sensible Junction Locations

Good transitions hinge on selecting the right places for them. Chimney breasts, internal partition walls, and other existing features can provide natural stop – start points for IWI. These locations help hide thickness changes and can reduce the amount of work required at the primary external junction.

The overall aim is to ensure the insulation layout feels intentional, not forced – something that becomes much easier when junctions align with the logic of the building.


A Practical, Workable Approach

Done badly, mixing insulation types can produce cold spots, damp risks and a fiddly install. Done well, it’s remarkably straightforward. The key principles are simple:

  • Minimise the number of EWI–IWI transitions
  • Ensure the systems overlap to maintain the thermal envelope
  • Use thinner internal returns where appropriate, rather than full-depth boards
  • Position junctions thoughtfully in relation to the building’s features

Follow those steps and a mixed insulation strategy can perform exceptionally well, even on complex or aesthetically sensitive buildings.