SPECIFICATION GENERATOR
Find out which low impact materials are right for your building project.
To discuss your project give us a call on 01392 861763
Your specification
Below you'll find your specification. If you would like to discuss this with us, please give us a call on 01392 861763.
Our suggested specification:-
- Existing brick wall, stripped of plaster (the overall thermal performance is similar for solid stone walls)
- 15-20mm Baumit KZP 65 levelling plaster, if required.
- 5mm Multipor Fix X710 adhesive plaster
- 100mm Multipor M4 mineral insulation board
- 5mm Multipor Fix X710 adhesive plaster, incorporating Baumit StarTex mesh
- 2mm Baumit RK70N or Baumit Klima Glatt finishing plasters
- Interior
Please check this spec’s suitability for your project before installation. Simply Contact us with your full construction type and location and we’ll do the rest.
(Use the shift button and scroll wheel to manipulate models)
U-Value
0.34 W/m2K